Set the multimeter for resistance at 10k ω 2 at room temperature and take a reading between the sensor leads.
Floor temperature sensor resistance.
Suitable for use in wet areas ip68.
Always ensure resistance matches the information on the product tag.
Try temporarily hooking up a new sensor to the control.
Pull the latch for the hood and open it making sure it is secure before letting go.
Every comfortzone electric underfloor heating thermostat should be set up with a floor temperature sensor probe to monitor the temperature of your floor.
Sensor wire should be between 7 000 ohms to 14 000 ohms.
Installing a new sensor is typically easier than moving or repairing the existing sensor.
3 meter floor temperature sensor probe for underfloor heating thermostat features works with a wide range of different thermostats.
Test 4 temperature sensor.
Look at the front of the engine block in the middle of the pulleys.
Warmup heating cables are constant wattage cables that should be tested on a 200 ohm scale.
Check the thermostat floor temperature sensor cable by disconnecting the floor sensor cable from the thermostat measure the sensor cable resistance in ohms using a digital multimeter.
The coolant temperature sensor is located on the engine block under the hood.
You will search for the sensor within the engine block itself using a drop light if you need help to see it better.
Please check the resistance values of your current sensor against the table cable has high rigidity allowing it to be easily passed through existing flexible conduit.
With the digital multimeter scale set at 20k ohms the ohms reading of the.
It can be used to measure air or floor temperature and is specifically designed to be used as a floor sensor.
Replacement floor temperature sensor suitable for a wide range of underfloor heating thermostats.
To ensure that your floor heating system will function properly always test the resistance of your wires with a digital multimeter set to 200 ohms before during and after installation.
The slab sensor 079 is commonly used for floor temperature sensing in floor heating applications.
Test the floor temperature sensors using a multimeter to verify accuracy of the sensors.
The thin casing allows for retrofit installation between tile spaces if necessary.
The resistance will vary according to the temperature i e the colder the sensor the higher the resistance.
The 3m remote sensor probe can be used with all of our thermostats that accept a remote sensor.
Works with a wide range of different thermostatsplease check the resistance values of your current sensor against the table below for compatibility 3 metre long cable cable has high rigidity allowing it to be easily passed through existing flexible conduit suitable for use in wet areas.