Caution water pressure is not to exceed 125 psi 8 6 bar water temperature is not to exceed 110 f 43 c.
Fleck 5600 metered water softener manual.
5600 water dispenser pdf manual download.
Water conditioner flow diagrams water conditioner flow diagrams service position backwash position preliminary rinse position brine position fleck 7 5600 service manual.
It was updated from the old mechanical meter to the 21st century sxt electronics.
Location of softener and drain the softener should be located close to a drain to prevent air breaks and back flow.
Only used on metered water softners it indicates water is flowing.
Drain cannot be elevated more than 36 inches or exceed 20 feet in length.
Manually index the softener control into the in service position and let water flow into the resin tank.
View and download fleck 5600 service manual online.
Programming the fleck 5600 meter valve.
Bypass valves always provide for the installation of a bypass valve if unit is not equipped with one.
Installation instructions for water softeners with fleck 5600 and 5600sxt.
The 5600 fleck valve is the most popular water softener control valve on the planet and offers a rigid noryl valve body with low power consumption and a precision piston seal spacer assembly.
It may clear up almost immediately or it may take a couple of hours.
Drain line is securely in place before the use of the water softener system.
When the system regenerates there will be increased flow via this tubing which may cause the tubing to become loose.
If you like the classic mechanical meter you will love the electronic version which has fewer parts and is virtually.
6 model 5600 5600 econominder model 5600 installation and start up procedures note.
Install the water softener with the inlet outlet and drain connections made according to manufacturer s recommendations and to meet applicable plumbing codes.
The brine tank should be located within 20 feet of the water softener.
Before start up a few simple steps must be followed to program the fleck 5600 meter valve.
Downflow softener 120v 60hz u s.
Once the water is cleared up a manual regeneration should be run.
5600 5600 econominder owner s manual for questions or in case of emergency please call your local service technician preferably the one who.