In table 5 1 1 2 correct the cross references to read as follows.
Fire sprinkler system inspection checklist.
All automatic fire sprinkler systems standpipe systems and fire pumps.
Personnel qualifications nfpa 25 makes the owner responsible for properly maintaining the building fire sprinkler system.
When it comes to your fire sprinkler system the nfpa 25 is the standard for inspection testing and maintenance of water based fire protection systems and compliance helps maximize integrity to avoid failure and ensure fast effective response in a fire emergency.
Regular testing is also required statewide through the illinois office of the state fire marshal s adoption of nfpa 101.
Here is the sprinkler inspection checklist you should follow with the help of a fire protection company.
If you are unsure of what needs to be inspected during the quarterly semi annual or annual fire sprinkler inspection then check out our list below.
Systems notes the following errors in the 2017 edition of nfpa 25 standard for the inspection testing and maintenance of water based fire protection systems.
This fire sprinkler inspection checklist is a complete package that can help inspectors perform daily weekly monthly quarterly and annual inspections.
The following procedures shall be performed at each required quarterly inspection of a fire sprinkler system.
Sprinklers are not painted or covered.
Monthly fire sprinkler inspections.
Fire sprinklers must be maintained and checked to make sure that they will react quickly to smoke heat and flames.
Otherwise you might not find out your sprinkler system is broken until it s too late.
Quarterly inspection checklist.
Fire sprinkler inspection report.
Monthly quarterly and yearly sprinkler system inspections are a major part of protecting your business from fire.
Inspection fire sprinkler systems nfpa 13 2373 circadian way santa rosa ca 95407 phone.
Standard for the inspection testing and maintenance of water based fire protection systems.
See nfpa 25 11 sec.
Make it your priority to inspect the sprinkler system s valves and gauges once a month.
Table 5 1 1 2 summary of sprinkler system inspection testing and maintenance item frequency reference.
Fire sprinkler system.
When they are properly maintained these systems reduce the risk of a person dying by 50 to 75 percent according to the congressional office of.
Life safety code section 9 75 2000 edition.
This list is applicable to both wet and dry pipe sprinkler systems.
Sprinkler is equipped with a guard if it subject to damage.
These inspections must be conducted by a fire safety professional who is certified and knowledgeable on the subject matter.