Fire Rated Drywall Control Joint

Cemco 093x Fire Rated Control Joint Youtube

Cemco 093x Fire Rated Control Joint Youtube

All Things Gypsumproper Use Of Control Joints

All Things Gypsumproper Use Of Control Joints

Fire Rated Vinyl V Expansion V Shaped Control Expansion Joint Cap Drywall Trims

Fire Rated Vinyl V Expansion V Shaped Control Expansion Joint Cap Drywall Trims

Https Www Americangypsum Com Sites Default Files Documents Ga 234 20control 20joints 20for 20fire Resistant 20rated 20systems Pdf

Https Www Americangypsum Com Sites Default Files Documents Ga 234 20control 20joints 20for 20fire Resistant 20rated 20systems Pdf

Emshield Wfr3 3 Hr Fire Rated Wall Expansion Joints Emseal

Emshield Wfr3 3 Hr Fire Rated Wall Expansion Joints Emseal

Drywall Expansion Joints Use Drywall Control Joints Or Expansion Joint Products To Prevents Cracks In Ceilings Walls

Drywall Expansion Joints Use Drywall Control Joints Or Expansion Joint Products To Prevents Cracks In Ceilings Walls

Drywall Expansion Joints Use Drywall Control Joints Or Expansion Joint Products To Prevents Cracks In Ceilings Walls

Section 20 4 ga 4 7 4 where a control joint occurs in an acoustical or fire rated system blocking shall be provided behind the control joint by using a backing material such as 5 8 in.

Fire rated drywall control joint.

See figure 2 non rated assembly. Drywall or veneer plaster control joint clarkdietrich 093 zinc control joint is applied between abutting gypsum panels and is used to relieve stresses of expansion and contraction of drywall and veneer plaster systems in large ceiling and wall expanses over 30 in length. A composite control joint with intumescent tape factory applied to one side of the back of the control joint. No drywall rips required no sealant required no mineral wool required ul listed joint system us patent 8 671 632 2.

Control joints for fire resistance rated systems control joints in gypsum panel product systems shall be installed where indicated on the plans or specifications. Control joints assist in relieving stresses in assemblies that can result in cracks and joint ridging. Installing a control joint in a fire resis tance rated gypsum board assembly. Fas 093x fire rated control joint cemco s fas 093x fire rated control joint is a composite control joint with intumescent tape factory applied to the back side of the control joint.

Us patents covering emseal s fire rated expansion joint product portfolio include. The fas 093x has been tested according to ul 2079 5th edition test for fire. In this design the wood studs on either side of the joint are set 21 2 inches apart on floor plates and three layers of 5. 15 9 mm type x gypsum board mineral fiber or other tested equivalent.

The fas 093x has been tested according to ul 2079 test for fire resistance of building joint systems and is used to relieve stresses of expansion and contraction of drywall interior partitions or ceilings running in a horizontal or vertical direction. Fire rated expansion joints that waterproof insulate block sound handle traffic and movement in a single product. Fire rated wall expansion joint emshield wfr2 wall fire rated 2 hours is a watertight fire rated dual sided primary seal for repair retrofit and new installation in structural expansion joints and construction joints in vertical plane wall and head of wall applications.

Https Www Pabcogypsum Com Sites Default Files Ga 234 2016 Pdf

Https Www Pabcogypsum Com Sites Default Files Ga 234 2016 Pdf

Design Details Details Page Dwss Expansion Joint Perpendicular Fire Rated

Design Details Details Page Dwss Expansion Joint Perpendicular Fire Rated

Section 11 Drywall Metal Framing And Plaster Engineering360

Section 11 Drywall Metal Framing And Plaster Engineering360

Fire Rated 093v Expansion Trim Tex Drywall Products

Fire Rated 093v Expansion Trim Tex Drywall Products

Source : pinterest.com