Peerless fire pump installations ul listed ulc listed or fm approved deliver superior fire protection to facilities worldwide.
Fire pump packing.
Coat each new packing ring with pak lube go jo or some type of liquid soap.
Centrifugal fire pump packing.
Posted in fire pumps general information and tagged extend pump service life packing gland adjustments on april 8 2016 by admin.
The packing gland should be placed on top of the packing.
Hale zm packing kit.
Field tested products are designed for reliability and longevity and include a broad selection of pumps drives controls baseplates and accessories.
Pentair aurora s commitment to fire suppression system performance and quality service goes beyond just 100 years of perfecting fire pump design.
If you have any questions about replacing fire pump packing or would prefer we perform the service for you simply pick up the phone and call us at 302 652 4722.
Products 6 sort by.
Are inside the building they see the drip and think that.
Proper pump packing installation.
166 32 0 add to cart.
If it is a horizontal split case there will be six rings of packing on both sides of the shaft and in order to keep the shaft lubricated water needs to drip past the shaft to keep it lubricated.
We also offer kits from patterson and fair banks please contact us with your pump information for purchasing.
Most fire pumps will have six rings of packing.
Feel the packing gland be careful of the rotating shaft to see if the packing gland is too hot or uneven which will result in damage to the pump shaft.
But as the pump and packing start to set in you can expect a couple years of consistent and reliable service.
Waterous fire pump packing cmu 1993 up wtrs.
You ll be confident that your system is ready to operate with real time monitoring and the added benefit of alerts and alarms notifications that you can configure.
Waterous mechanical seal kit.
When people such as maintenance crews etc.
Gain system design advantages by leveraging our expertise in evolving standards and local fire codes.
Replace worn shaft sleeve if needed.
Adjust the followers one flat or of a turn every 30 minutes or until the leakage is controlled.
Repacking and regular maintenance is import for protecting your building as well as preventing expensive repairs later.
Tighten down the followers.
263 43 0 add to cart.
Stocking packing for your waterous hale darley c entrifugal fire pump.
Peerless fireconnect allows you to access complete fire pump system information 24 7 anytime and anywhere via your smartphone tablet laptop or desktop.
Packing adjustment will be more frequent at first.
Post navigation fire pump parts accessories availability hubbell launches a new line of metron fire pump controllers.