Article 14 of the fso has many sub sections to ensure that the escape routes and exits within a building are sufficient in type width number location and that the exit doors are fitted with the correct door furniture and open in the right direction where necessary.
Fire exit door width.
Objects that project into the exit must not reduce its width.
Where there is only one exit access leading to an exit or exit discharge the width of the exit and exit discharge must be at least equal to the width of the exit access.
A door or doorway is the clear width when the door is open see diagram c1.
Does a 30 inch wide pair of doors have a clear width of 60 inches.
An exit access must be at least 28 inches wide at all points.
A stair is the clear width between the walls or balustrades.
The nfpa emergency exit door requirements code states there is a maximum travel distance allowed to find an exit.
There are specific requirements for electronically controlled egress doors.
An escape route is the width at 1 500 mm above floor level when defined by walls or elsewhere the minimum width of passage available between any fixed obstructions.
What are the maintenance safeguarding.
The width of the exit and exit discharge must be at least equal to the width of the exit access.
It is important that each floor plan of a building indicates the shortest route s to a place of comparative or ultimate safety should an emergency evacuation be triggered e g.
This doesn t mean that a pair of 30 inch wide doors is sufficient because of the requirements for multiple exit locations and minimum clear width read on i m a little confused.
1910 36 g 3 the width of an exit route must be sufficient to accommodate the maximum permitted occupant load of each floor served by the exit route.
An applied force not to exceed 15 pounds will cause the door latch to release.
Panic hardware and fire exit hardware consist of bars that must extend across not less than one half the width of the door leaf not less than 30 inches or more than 44 inches above the floor.
So the egress doors serving that space must have a total of 60 inches of clear width.
The width of final exit doors and the escape routes leading to them will dictate the maximum number of people who can safely occupy.
Issue 4 2012 detailing the requirements for any fixtures and fittings used with fire doors and fire.
If there is a fire in the area where occupants are they are already being exposed to smoke fire and heat.
There is an approved document guidance available from the builders hardware industry federation bhif hardware for fire and escape doors.
Side hinged exit doors must be used to connect rooms to exit routes.
These doors must swing.
Approved fire door that remains closed or automatically closes in an emergency.