A 1 1 see annex k for general information about fire doors.
Fire door certification requirements.
Sign up for the dhi training course contact the iqp administrator.
In north american building codes it along with fire dampers is often referred.
The certified door dealer consultant program is the industry s first independent comprehensive training and certification program for manufacturer sales representatives.
The importance of fire doors a fire door is a vital safety device engineered to save lives and property.
The locks or closing mechanisms on each door have been fire tested and certified remember all fire doors must be self latching.
Some changes are allowed within the certification scope of the fire door leaf.
A fire door is a door with a fire resistance rating sometimes referred to as a fire protection rating for closures used as part of a passive fire protection system to reduce the spread of fire and smoke between separate compartments of a structure and to enable safe egress from a building or structure or ship.
Becoming a qualified fire door inspector to become a qualified fire door inspector through the iqp program participants must first complete dhi s dai 600 course.
This one hour self paced module is based on the 2016 edition of nfpa 80.
Nfpa 80 standard for fire doors and other opening protectives 2010 edition.
All furniture handles and any other fixture fitted to the door leaf must be tested and certified locks must have a 127mm back set.
Standard for fire doors and other opening protectives to locate interpret and correctly identify and apply the requirements for the inspection testing and maintenance of fire door assemblies.
This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls floors and ceilings against the spread of fire and smoke within into or out of buildings.
Basis of requirements nfpa 101 requires annual fire and smoke door inspections section 18 19 2 2 2 1 sections 18 19 2 2 1 require compliance with section 7 2 1 which includes 7 2 1 15 2 section 7 2 1 15 2 requires compliance with.
It is not a mandatory requirement to be certificated if making certain changes to fire doors manufactured under the bwf certifire fire door scheme.
With nfpa 80 requiring fire door inspections by inspectors certified by a program such as the door and hardware institute s fire and egress door assembly inspection program ensuring that they have the required clearances and operations can be challenging because not all fire doors are used on a regular basis.
The course provides new hires with an in depth examination of door and access systems dealers and an overview of the industry and its many components.
Upon completion you should be able to.