The breakers inside the panel are designed to guard your home against serious electrical problems by preventing circuit overload short circuits and outside power surges coming into.
Federal pacific stab lok breaker panel.
However although the panel had benefits issues began to emerge as some officials suspected that the panel was causing house fires.
The most popular breaker panel installed was the federal pacific stab lok breaker panel also known as the fpe stab lok breaker panel.
Federal pacific electric stab lok panels have a long history of problems.
Ul standards require that breakers trip or shut off the current when overloaded to prevent electrical.
1 pole federal pacific stab loc type na replacement circuit breaker.
According to the united states consumer product safety commission fpe stab lok residential circuit breakers may fail to trip properly with overload and short circuiting underwriters laboratories inc.
The main panel federal pacific sold was the stab lok named after its breaker functionality.
They are typically clearly labeled with the words federal pacific electric or fpe also when you open the door you will often see the words stab lok in the center or on the side of the breaker panel.
The breakers would stab into slots in the bus bar and lock into place.
Federal pacific stab lok breaker panels are normally easy to recognize.
Federal pacific electric stopped manufacturing fpe stab lok products under its own name and eventually sold the name rights.
Alternative methods for replacement of federal pacific stab lok fpe electric panels.
Stab lok circuit breakers federal pacific electric panel replacement recalls lawsuits and decades of failed inspections have once again brought federal pacific electric fpe stab lok circuit breakers under intense scrutiny over their inherent fire and safety hazards.
The federal pacific stab loc circuit breaker has a history of problems with the circuit breakers however replacement fpe circuit breakers are still available.
If you have one of these electric panels in your home or you re buying a home with one of these panels you should have.
If your home was built between 1950 and 1990 and is equipped with a federal pacific electric fpe circuit breaker panel with stab lok circuit breakers you run a significant risk of breaker malfunction and fire.
Some of the problems with the fpe circuit breakers are due to the contact point connection with the panel buss and in some cases the contact inside the circuit breaker have failed due to.
Federal pacific new ubif thick 50 amp 1 in.